- Model NO.: MGP-1000KV-10GA-SJ4
- Conductor Circuit: Double Circuit
- Materials: Steel
- Style: Independence Tower
- Design Software: Pls
- Accessories 2: Conductor and Cable
- Accessories 4: Tower Foundation and Design
- Accessories 6: Tower Earthing Kits and Lightning Rod
- Transport Package: Export Standard Package
- Origin: Shandong, China
- Usage: Crossing Tower, Tension Tower, Angle Tower, Terminal Tower, Transposition Tower, According to Client Requirements
- Certification: ISO
- Standard: Nonstandard
- Structure: According to Client Requirements
- Accessories 1: Power Fitting
- Accessories 3: Earth Wire and Opgw
- Accessories 5: Aviation Light
- Trademark: MEGATRO
- Specification: As per client requirements
- HS Code: 73082000
This photo refers to our 1000KV 10GC-SJ4 DC heavy angle tension and tubular tower, it is widely used in our Chinese market. Some of technical features of this tower as follow:
1 climate condition
Item | Temperature (ºC) | Wind speed (m/s) | Ice thickness (mm) |
Max. temperature | 40 | 0 | 0 |
Mini. temperature | -15 | 0 | 0 |
Ice thickness | -5 | 10 | 0 |
Basic wind speed | -5 | 32 | 10/15 |
Installation condition | 15 | 10 | 0 |
Annual temperature | 15 | 15 | 0 |
Lightning overvoltage | 15 | 16 | 0 |
Operation overvoltage | -10 | 10 | 0 |
Item |
Conductor | OPGW | |
JLJ-630/45 | JLB40-150 | ||
construction |
AL | 45/4.20 | --- |
Steel(Al wrap steel ) | 7/2.8 | 19/4 | |
Cross-section (mm2) |
Al | 666.55 | 238.76 |
Steel | 33.6 | 20 | |
Total | 2.06 | 1.5935 | |
Diameter | 141266 | 247010 | |
Length mass (kg/km) | 0.04633 | Â | |
Elastic module (MPa) | 63000 | 147200 | |
coefficient of linear expansion (1/ºC) | 20.9×10-6 | 13.0×10-6 |
Tower type |
Nominal Height Scope (mm) |
Horizontal span (m) |
Vertical Span (m) |
Angle º |
Nominal height tower weight Kg |
10GC-SJ4 | Â | 450 | 250-600 | 60~90 | 419.1 |
Power voltage |
1000KV Â |
Conductor type |
8×JLJ-630/45 |
Max. operation Tension force (KN/phase) |
452.048 |
Un-balance Stress value(%) |
20 |
OPGW Type |
JLB40-150 |
Max. operation Tension force (KN/pc) |
65.002 Â |
Un-balance Stress value(%) |
100 Â |
Item  |
Horizontal span (m) |
Vertical Span (m) |
Representative Span (m) |
Angle º |
Height (m) |
KV Â |
data | 450 | 600 | 300-600 | 60~90 | 48 | / |
Site condition |
Normal operation condition | Accident condition |
Installation condition |
||||||
Basic wind speed | Ice |
Mini. temperature |
Non- broken |
broken | |||||
Climate condition (t/v/b) |
-5/38.15/0 | -5/10/15 | -15/0/0 | Â | Â | 0/10/0 | |||
Horizontal loading | conductor | 113935 | 21208 | 0 | Â | Â | 10671 | ||
Insulator Power fitting |
---- | ---- | ---- | Â | Â | Â | |||
Jump & string | ---- | ---- | ---- | ---- | ---- | ---- | |||
OPGW | 9696 | 3263 | 0 | Â | Â | 2351 | |||
Vertical loading  |
conductor | 208585 | 2922801 | 208585 | Â | Â | 208585 | ||
Insulator Power fitting |
---- | ---- | ---- | ---- | ---- | ---- | |||
Jump & string | ---- | ---- | ---- | ---- | ---- | ---- | |||
OPGW | 11765 | 22397 | 11765 | Â | Â | 11765 | |||
Climate condition (t/v/b) |
-5/38.15/0 | -5/10/15 | IDC Connector Waterproof Connector,Idc Connector,Idc Socket Connector,Horizontal Waterproof Idc Socket Connector Shenzhen Jinyicheng Electronci Technology Co.,Ltd. , https://www.jycconnector.com |