![]()
Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
![]()
Electronic scale crystal oscillator 3.2*2.5mm 3225 16M (16.000MHZ) 12PF 10PPM 20PPM 30PPM
![]()
Photocoupler
Fluke 985 Air Dust Particle Counter Function
Fluke 985
Air dust particle counter
New type
Fluke 985
Air dust particle counter is
HVAC
with
IAQ
The tool of choice for experts. From filtering test to
IAQ
survey,
Fluke 985
It is the best portable solution for determining the concentration of airborne particles. use
Fluke 985
An immediate response to occupant complaints is part of a comprehensive preventive maintenance program.
use
Fluke 985
,you can:
Measuring filtration efficiency
Monitoring industrial clean room
Pre-screening indoor air quality, rest assured
IAQ
Expert cooperation
Target the particle source for repair
Report the effectiveness of the repair to the user
Drive additional business by demonstrating maintenance and repair needs
Fluke 985
The large display, intuitive navigation icons and on-screen data display allow users to test faster, reducing the time it takes to browse the screen for data.
Fluke 985
Lightweight, can be used anywhere, and used
USB
Cables and memory sticks make it easy to output data. View and analyze data easily and anytime, anywhere.
Easier and more accurate assessment of air quality.
have
6
Channels, the particle size range is
0.3 - 10.0 μm
:
Even if it is required
ISO Class 5 – 9
Accurate measurement can also be performed on important areas of certification
Ultra-lightweight, ergonomically designed:
One-handed operation is easy in narrow or inconvenient areas, reducing operator fatigue
Long battery life:
Under standard usage, the battery power is
10
Hours to ensure full day work
3.5 QVGC
Large color display:
Easy navigation and viewing with intuitive icons and large font options
Storage record
10000
Article:
Quick access to historical data
The screen data shows:
Users can choose to view data in traditional table or trend graphs based on their preferences.
Personalized settings and configuration:
Customizable display, sampling method, and sample statistics alert settings
Data output options:
use
USB
Memory stick,
USB
A cable or Ethernet connection downloads the data to a personal computer. No special software is required to download or view data
Option password control:
Confirm safety if necessary
USB/
Ethernet charging dock:
Make sure the device is ready to use
Measurement specification
aisle
0.3
μ
m, 0.5
μ
m, 1.0
μ
m, 2.0
μ
m, 5.0
μ
m, 10.0
μ
m
flow
0.1 cfm (2.83 L/min)
light source
775 nm
to
795 nm
,
90mW 3B
Laser
Counting mode
Raw count, cumulative or differential mode
#/m3
,
#/ft3
,
#/L
Counting efficiency
50 % @ 0.3
μ
m
;
> 0.45
μ
m
Particles for
100%
(according to
ISO 21501
)
Zero count
Count every five minutes
(JIS B9921)
Concentration limit
Per cubic foot
4000000
Particles
10 %
(according to
ISO 21501
)
data storage
10000
Record (rotation buffer)
alarm
Count, low battery, sensor failure
delay
0
to
twenty four
hour
Sample entry
Isotropic motion probe
Safety
Administrator password control (optional)
Communication mode
USB
Or Ethernet
Size (long
x
width
x
high)
27.2 cm x 9.9 cm x 5.3 cm (10.7 in x 3.9 in x 2.1 in)
weight
0.68 kg (1.5 lb)
Power Adapter
100 V ac
to
240 V ac
,
12 V dc
,
2.5 A
rechargeable battery
lithium battery
7.4 V 2600 mAh
;
10
Hour standard use time (
5
Continuous sampling for hours)
/ 3.5
hour
calibration
in the air
PSL
particle
(
NIST
Traceable)
working environment
50 °F
to
104 °F (10 °C
to
40 °C) /
Non-condensing relative humidity is less than
95%
Storage environment
14 °F
to
122 °F (-10 °C
to
50 °C)/
Non-condensing relative humidity is less than
98%
warranty period
1
year
Attachment includes
Charging stand, convenient
USB
And Ethernet communication,
ENET CAT5E 7
Foot cable,
USB-A
to
MINI-B 6
Foot cable,
12 V
DC power supply, zero count inlet
-
Filters, filter fittings, sample inlet covers, hard-carrying boxes, starter manuals and user manuals
CD
Model Name
description
Price List
Fluke 985
The complete set of particle counters includes:
Getting Started Manual and User Manual
CD
Charging stand and portable
USB
And Ethernet communication pieces
ENET CAT5E 7
Foot cable
USA-A
to
MINI-B 6
Foot cable
12 V
DC power supply
Zero count inlet filter
Filter connector
Sample inlet protection cover
Hard carrying case
Keywords: dust particle counter, suspended particle tester, air particle, particle analysis, instrumentation, purification engineering, pharmaceutical engineering, pharmaceutical machinery, bioengineering, biological equipment
KNB1-32 Mini Circuit breakers, also named as the air switch which have a short for arc extinguishing device. It is a switch role, and also is a automatic protection of low-voltage electrical distribution. Its role is equivalent to the combination of switch. Fuse. Thermal Relay and other electrical components. It mainly used for short circuit and overload protection. Generally, According to the poles, mini Circuit breaker can be divided into 1P , 1P+N , 2P, 3P and 4P.
KNB1-32 Miniature Circuit Breaker,KNB1-32 Electronics Miniature Circuits Breaker,KNB1-32 Automatic Miniature Circuit Breaker,KNB1-32 Mini Circuit Breaker